Braz. dent. j ; 33(6): 78-85, Nov.-Dec. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420562

ABSTRACT

Abstract The aims of this clinical study were to evaluate the Color change - ΔE (based on spectrophotometry and visual analysis) and luminosity - L* (based on spectrophotometry) of dental enamel surface (after orthodontic treatment) around the area where orthodontic brackets were fixed, based on different cementing materials such as a resin (R group) and resin-modified glass ionomer cement (RMGIC group). The split-mouth study initially comprised 14 patients. Orthodontic brackets were fixed to the upper central incisors with resin or RMGIC. The color of the buccal surface of each tooth was measured through spectrophotometry and visual examination before the bracket-fixation process. Four individuals were excluded during the follow-up; thus 10 patients were evaluated (n=10). Brackets were removed after 12 months of orthodontic treatment, tooth color measurement and visual examination were performed again, and Adhesive Remaining Index (ARI) was also measured. ΔE and L* results were subjected to Student's t-test and by repeated-measures analysis of variance, respectively (α=0.05). ARI data were analyzed in percentages. There was statistically significant difference in ΔE between groups; the R group showed statistically higher values of L* after orthodontic treatment. ARI of 2 and 3 prevailed in the RMGIC group, whereas the R group presented 0 and 1. After orthodontic treatment, the RMGIC group presented smaller changes in ΔE, and the increase in the white scale was observed on the enamel surface around the area where brackets were fixed in the R group. The visual analysis did not show color change on the evaluated teeth.


Resumo Os objetivos deste estudo clínico foram avaliar a alteração de cor - ΔE (baseada em espectrofotometria e análise visual) e luminosidade - L* (baseada em espectrofotometria) da superfície do esmalte dentário (após tratamento ortodôntico) ao redor da área onde os braquetes ortodônticos foram fixados, com base em diferentes materiais de cimentação, como resina (grupo R) e cimento de ionômero de vidro modificado por resina (grupo RMGIC). Estudo boca dividida foi inicialmente composto por 14 pacientes. Os braquetes ortodônticos foram fixados nos incisivos centrais superiores com resina ou RMGIC. A cor da superfície vestibular de cada dente foi mensurada por espectrofotometria e avaliada por exame visual antes do processo de fixação dos braquetes. Quatro indivíduos foram excluídos durante o acompanhamento; assim, 10 pacientes foram avaliados (n=10). Os braquetes foram removidos após 12 meses de tratamento ortodôntico, a mensuração da cor do dente e o exame visual foram realizados novamente, e o Índice de Remanescente do Adesivo (IRA) também foi mensurado. Os resultados ΔE e L* foram submetidos ao teste t de Student e à análise de variância para medidas repetidas, respectivamente (α=0.05). Os dados do ARI foram analisados em porcentagens. Houve diferença estatisticamente significativa no ΔE entre os grupos; o grupo R apresentou valores estatisticamente maiores de L* após o tratamento ortodôntico. O IRA 2 e 3 prevaleceu no grupo RMGIC, enquanto o grupo R apresentou 0 e 1. Após o tratamento ortodôntico, o grupo RMGIC apresentou menores alterações no ΔE e o aumento da escala branca foi observado na superfície do esmalte ao redor da área onde os braquetes foram fixados no grupo R. A análise visual não mostrou mudança de cor nos dentes avaliados.

2.
Braz. dent. j ; 33(5): 74-80, Sep.-Oct. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1403788

ABSTRACT

Abstract The longevity of prosthetic rehabilitation is determined by the stability of the implant and abutment interfaces. True morse taper connections on dental restorations have been effective, however activation force still empirical. This work compared the activation strength and internal contact of Morse taper system according to the removal force. Eighty sets, composed of implants and prosthetic abutments, were evaluated with different internal contact areas; 15.12mm2 (G3.3) and 21.25mm2 (G4.3). The specimens were activated at 0° and 30°, with loads of 10, 20, 40 and 60N. The specimens were submitted to tensile test and the data to ANOVA and Tukey's tests (α=0.05). Representative specimens were examined under SEM. Removal force of G3.3 (2.15±1.33MPa) did not differed to G4.3 (1.99±1.03MPa). The activation at 0º (2.95±0.98MPa) statistically differed to 30º (1.19±0.54MPa). The 60N load was statistically superior for G3.3 and there was no statistical difference between 20N to 60N in G4.3. The values of 10N at 30o and 20N at the long axis of the morse taper implant, independent of the frictional contact area showed the best settlement.


Resumo A longevidade da reabilitação protética é determinada pela estabilidade das interfaces implante e pilar. Conexões de cone Morse em restaurações dentárias têm se mostrado eficazes, porém a força de ativação ainda é empírica. Este trabalho comparou a força de ativação e contato interno do sistema cone Morse de acordo com a força de remoção. Oitenta conjuntos, compostos por implantes e pilares protéticos, foram avaliados com diferentes áreas de contato interno; 15,12mm2 (G3.3) e 21,25mm2 (G4.3). Os corpos-de-prova foram ativados a 0° e 30°, com cargas de 10, 20, 40 e 60N. Os corpos de prova foram submetidos ao ensaio de tração e os dados aos testes ANOVA e Tukey (α=0,05). Espécimes representativos foram examinados em MEV. A força de deslocamento do G3.3 (2,15±1,33MPa) não diferiu do G4.3 (1,99±1,03MPa). A ativação a 0º (2,95±0,98MPa) diferiu estatisticamente para 30º (1,19±0,54MPa). A carga de 60N foi estatisticamente superior para G3.3 e não houve diferença estatística entre 20N a 60N no G4.3. Os valores de 10N em 30o e 20N no longo eixo do implante cone morse, independente da área de contato friccional apresentaram o melhor assentamento.

3.
Braz. oral res. (Online) ; 36: e037, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1364588

ABSTRACT

Abstract: This paper evaluates the physicochemical and biological properties of experimental resin-based dual-cured calcium aluminate (CA) and calcium titanate (CTi) materials for vital pulp therapy (VPT). The experimental dual-cured materials were obtained as two pastes: a) Bis-EMA 10, PEG 400, DHEPT, EDAB, camphorquinone, and butylated hydroxytoluene; and b) fluoride ytterbium, Bis-EMA 10, Bis-EMA 30, benzoyl peroxide, and butylated hydroxytoluene. The materials were divided into six groups based on the added calcium component: MTA (MTA®, Angelus); CLQ (Clinker-Fillapex®, Angelus); CA (calcined at ,1200°C in pastes a and b); CA800 (calcined at 800°C in paste a); CA1200 (calcined at 1,200°C in paste a); and CTi (paste a). The real-time degree of conversion and rate of polymerization (n = 3), diametral tensile strength (n = 10), hydrogen potential (n = 15), calcium ion release (n = 10), water sorption and solubility (n = 10), and cell viability (n = 6) were evaluated. One- and two-way ANOVA and Tukey's post hoc test were used in the analysis of the parametric data, and Kruskal-Wallis and Dunn's multiple tests were used to analyze the nonparametric data (α = 0.05). CLQ, CA800 and CA1200 had the highest diametral tensile strength. The water solubility of MTA was similar to that of CA800, CA1200 and CTi. CA800 and CA1200 resulted in cell viabilities similar to those of MTA and CLQ. The experimental dual-cured CA-based material that calcined at 800°C showed physicochemical and biological properties suitable for VPT, and similar to those of MTA.

4.
Braz. dent. j ; 32(5): 34-40, Sept.-Oct. 2021. tab
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1350285

ABSTRACT

Abstract The aims of this in vivo study were to evaluate the effect of bonding with resin-modified glass ionomer cement (RMGIC) and to assess enamel surface roughness before and after the removal of brackets bonded with composite or RMGIC from the maxillary central incisors. Fifteen orthodontic patients were selected for the study. For each patient, the teeth were rinsed and dried, and brackets were bonded with composite (Transbond XT) and RMGIC (Vitremer Core Buildup/Restorative). At the conclusion of orthodontic treatment, their brackets were removed. Dental replicas were made of epoxy resin in initial conditions (before bonded) and after polishing with an aluminum oxide disc system. Adhesive remnant index (ARI) and surface roughness was measured on the dental replicas and data were evaluated statistically by Mann-Whitney and paired t-test, respectively. No bracket debonding occurred during patients' treatment periods. It was verified that the ARI values of the two maxillary central incisors were similar (p = 0.665). For both bonding materials, the ARI value of 3 was predominant. After polishing, surface roughness was similar in the composite and RMGIC groups (0.245 μm and 0.248 μm, respectively; p = 0.07). In both groups, enamel surface roughness values were significantly lower after polishing compared with the initial condition (p < 0.001). RMGIC promoted efficiency in cementing brackets without fail during treatment; the choice of composite or RMGIC materials was not a factor that influenced the roughness of the enamel surface, however, polishing led to smoother surfaces than those found at the beginning of the treatment.


Resumo Os objetivos deste estudo in vivo foram avaliar o efeito da colagem com cimento de ionômero de vidro modificado por resina (CIVMR) e a rugosidade da superfície do esmalte antes e após a remoção dos braquetes colados com compósito ou CIVMR em incisivos centrais superiores. Quinze pacientes ortodônticos foram selecionados para o estudo. Para cada paciente, os dentes foram lavados e secos, e os braquetes colados com compósito (Transbond XT) e CIVMR (Vitremer Core Buildup / Restorative). Ao término do tratamento ortodôntico, os braquetes foram removidos. As réplicas dentais foram confeccionadas em resina epóxica nas condições iniciais (antes da colagem) e após o polimento com sistema de discos de óxido de alumínio. O índice de remanescente adesivo (IRA) e a rugosidade da superfície foram mensurados nas réplicas dentais e os dados foram avaliados estatisticamente por Mann-Whitney e teste t pareado, respectivamente. Não ocorreu descolagem de braquetes durante os períodos de tratamento dos pacientes. Verificou-se que os valores do IRA dos dois incisivos centrais superiores foram semelhantes (p = 0,665). Para ambos os materiais de colagem, o valor de IRA predominante foi 3. Após o polimento, a rugosidade da superfície do esmalte foi semelhante nos grupos compósito (0,245 μm) e CIVMR (0,248 μm) (p = 0,07). Em ambos os grupos, os valores de rugosidade da superfície do esmalte foram significativamente menores após o polimento em comparação com a condição inicial (p <0,001). CIVMR promoveu eficiência na colagem de braquetes sem falhas durante o tratamento; a escolha dos materiais compósito ou CIVMR não foi um fator que influenciou na rugosidade da superfície do esmalte, porém, o polimento levou a superfícies mais lisas do que as encontradas no início do tratamento.

5.
Acta odontol. latinoam ; 34(3): 226-232, 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383409

ABSTRACT

ABSTRACT The aim of this study was to compare the microshear bond strength of different resin cements to CAD/CAM-created lithium disilicate ceramics after 24 hours and after 1 year (10,000 thermocycles). Forty (40) ceramic bars were subjected to pretreatment comprising airborne abrasion with aluminum oxide particles, etching with 10% hydrofluoric acid and Monobond N application. Bars were divided into 4 groups (n = 10), based on cement type: light-cured Variolink Esthetic LC (VLC) and dual-cured Variolink N (VN) at two different times: after 24 hours and after 1 year. Silicone molds were used to prepare cement cylinders on a ceramic surface. The set was stored in distilled water at 37ºC, for 24 hours or subjected to 10,000 thermocycles. The molds were removed and microshear bond strength was tested. Data were submitted to two-way analysis of variance and Tukey's test (α = 0.05). Based on the comparison between cement values at different aging times (p = 0.035), VN after 24 hours (27.10 ± 0.92) and after 1 year (20.62 ± 1.25) presented significantly higher values than VLC after 24 hours (14.79 ± 0.76) and after 1 year (6.61 ± 0.81). Bond strength recorded for both cements after 24 hours (VN: 27.10 ± 0.92 and VLC: 14.79 ± 0.76) was significantly higher than the one recorded after 1 year (VN: 20.62 ± 1.25 and VLC: 6.61 ± 0.81). The thermocycling reduced the values observed for both investigated cements; bond strength was greater for dual-cure resin cement than for light-cured resin cement.


RESUMO O objetivo nesse estudo foi comparar a resistência de união de diferentes cimentos resinosos à cerâmica de dissilicato de lítio processada por CAD/CAM após 24 horas e após 1 ano (10.000 termociclos). Foram utilizadas 40 barras cerâmicas com tratamento prévio por jateamento com óxido de alumínio, condicionamento com ácido fluorídrico 10% e aplicação do Monobond N. As barras foram divididas em 4 grupos (n=10) de acordo com o tipo de cimento: fotopolimerizável Variolink Esthetic LC (VLC) e dual Variolink N (VN) em diferentes tempos: após 24 horas e 1 ano. Matrizes de silicone foram usadas para preparar cilindros de cimento na superfície cerâmica. O conjunto foi armazenado em água destilada a 37ºC por 24 horas ou submetidos protocolo de termociclagem com 10.000 ciclos. As matrizes foram removidas e o teste de microcisalhamento realizado. Os dados foram avaliados por análise de variância a dois fatores e teste de Tukey (α=0,05). Ao comparar os valores dos cimentos em diferentes tempos de envelhecimento (p=0,035), observou-se que VN, após 24 horas (27,10 ± 0,92) e 1 ano (20,62 ± 1,25) apresentou valores significativamente superior a VLC após 24 horas (14,79 ± 0,76) e 1 ano (6,61 ± 0,81). A resistência para ambos os cimentos após 24 horas (VN: 27,10 ± 0,92 e VLC: 14,79 ± 0,76) foi significativamente superior que 1 ano (VN: 20,62 ± 1,25 e VLC: 6,61 ± 0,81). A termociclagem promoveu diminuição nos valores de ambos os cimentos estudados e o cimento resinoso dual mostrou maior resistência de união que o cimento resinoso fotopolimerizável.

6.
Braz. dent. j ; 30(5): 453-458, Sept.-Oct. 2019. graf
Article in English | LILACS | ID: biblio-1039141

ABSTRACT

Abstract The aim of this study was to analyze the effects of MTA on the structure and enzymatic activity of sPLA2 in order to provide subsidies for improvement in the formulation of the product. MTA powder was incubated for 60 min in the presence of sPLA2 and was analyzed by chromatography, electrospray mass (ESI-MS) and small-angle X-ray scattering (SAXS). It was find that the elution profile, retention time, and fragmentation of sPLA2 were altered after treatment with MTA. Calcium was the MTA component that most amplified the inflammatory signal. Significant interactions were found between MTA and sPLA2, which could aid in our understanding of the mechanisms of action of MTA during the inflammatory process and it may facilitate the structural modification of MTA, thereby improving its biological safety and consequently the rate of the treatment success.


Resumo O objetivo deste estudo foi analisar os efeitos do MTA na estrutura e atividade enzimática da sPLA2 a fim de fornecer subsídios para melhoria na formulação do produto. O MTA em pó foi incubado por 60 min na presença de sPLA2 e analisado por cromatografia, espectroscopia de massa por eletropulverização (ESI-MS) e espalhamento de raios-X de baixo ângulo (SAXS). Encontrou-se que o perfil de eluição, o tempo de retenção e a fragmentação da sPLA2 foram alterados após o tratamento com MTA. O cálcio foi o componente do MTA que mais ampliou o sinal inflamatório. Encontraram-se interações significativas entre o MTA e o sPLA2, o que poderia auxiliar na compreensão dos mecanismos de ação do MTA durante o processo inflamatório e facilitar a modificação estrutural do MTA, melhorando sua segurança biológica e consequentemente a taxa de sucesso do tratamento.


Subject(s)
Root Canal Filling Materials , Oxides , X-Ray Diffraction , Silicates , Calcium Compounds , Aluminum Compounds , Drug Combinations , Scattering, Small Angle
7.
Braz. j. oral sci ; 17: e181207, 2018. tab
Article in English | LILACS, BBO | ID: biblio-970477

ABSTRACT

Aim: The aim of this study was to evaluate and compare the setting times (ST), flow (FW), radiopacity (RP), dimensional stability (DS), solubility (SB), and polymerization stress (PS) of the MTA Fillapex and AH Plus root canal sealers. Methods: The above qualities were tested according to ISO 6876/2001 standardization. The water used in the dimensional stability test was evaluated to verify the presence of released materials. For the photoelastic analysis, 20 photoelastic resin rings were prepared, and the root canal sealers were inserted. After 24 hours, the specimens were analyzed in a Polariscope. Data of the setting times, flow tests, radiopacity, dimensional stability, and solubility tests were submitted to a Kolgomorov­Smirnov test and then to a Student's t-test at the 5% significance level. Results: The data derived from photoelastic analyses were submitted to an ANOVA and Tukey's test with a significance level of 5%. MTA Fillapex and AH Plus complied with ISO 6876/2001. However, there were significant differences (p < 0.05) between the two cements for ST, FW, RP, DS, and SB. MTA Fillapex showed higher FW, SB, and PS when compared with AH Plus. Conclusions: MTA Fillapex and AH Plus complied with ISO 6876/2001 in terms of ST, FW, RP, DS, and SB. MTA Fillapex showed higher PS when compared to AH Plus


Subject(s)
Root Canal Obturation , Surface Properties , Dental Materials , Endodontics
8.
J. health sci. (Londrina) ; 19(3)31/10/2017.
Article in Portuguese | LILACS | ID: biblio-876140

ABSTRACT

Em endodontia, indicam-se substâncias quelantes para a remoção da lama dentinária. O objetivo deste estudo foi avaliar, in vitro, por meio do microcisalhamento, a resistência de união da resina composta com superfícies dentinárias tratadas com EDTA (17%) e quitosana (0,2%). De 30 coroas de dentes bovinos foram removidas as paredes palatina, mesial e distal, expondo a superfície dentinária da parede vestibular da câmara coronária, que abrasionada produziu a camada de esfregaço. Após, a superfície foi tratada, estabelecendo-se 3 grupos (n=10): G1 (controle) com aplicação de água destilada (1min); G2 com aplicação de EDTA (3 min.), e lavagem com água destilada (1 min.); e G3 com aplicação de quitosana (3 min.), lavagem com água destilada (1 min.). Na sequência foram aplicados 2 ml de NaOCl (2,5%), 2 ml de água destilada (1 min), armazenando-as em água destilada (37 °C). Retiradas da água destilada (24 h), fixaram ­se 3 tubos Tygon (1mmX1mm) na dentina após o condicionamento local com sistema adesivo convencional de 2 passos. Preenchidos com resina composta e após fotoativação, os tubos foram removidos obtendo-se cilindros que foram submetidos ao microcisalhamento em máquina de ensaio universal. Os resultados de resistência de união (MPa) foram submetidos a Análise de Variância e Tukey, com nível de significância 5%. Observou-se que a resistência de união de G2 e G3 foram equivalentes estatisticamente (p>0,05), porém significativamente maiores que em G1 (p<0,05). Conclui-se que quitosana e EDTA promovem resistência de união semelhante nas condições testadas. (AU).


In endodontics, chelating substances are indicated for smear layer removal. This study evaluated, by micro-shear, the bond strength between composite resin and dentin surfaces treated with EDTA (17%) and chitosan (0.2%). The palatal, mesial and distal walls were removed from 30 crowns of bovine teeth, to expose buccal dentin of coronary chamber, whose abrasion produced the smear layer. The surface was treated, considering 3 groups (n = 10): G1 (control) distilled water (1min); G2 EDTA application (3 min), and distilled water (1 min); and G3 chitosan application (3 min.), distilled water (1 min.). All groups received 2 ml of NaOCl (2.5%), 2 ml of distilled water (1 min), and then stored in distilled water (37 °C). After that (24 h), 3 Tygon matrix (1 mmX1 mm) were fixed to the dentin after surface storing them with a two-step adhesive system. Then, the matrixes were filled with composite resin, and once photoactivated, the matrix were removed resulting in cylinders that were submitted to micro-shear bond test in universal test machine. The results (MPa) were submitted to ANOVA and Tukey, with significance level of 5%. It was observed that G2 and G3 bond strength were statistically equivalent (p> 0.05), but significantly higher than G1 (p <0.05). It is concluded that chitosan and EDTA resulted in similar bond strength under the conditions tested. (AU).

9.
J. health sci. (Londrina) ; 19(4)30/10/2017.
Article in Portuguese | LILACS | ID: biblio-877738

ABSTRACT

Este estudo avaliou a necessidade e uso de prótese entre 504 idosos independentes, cadastrados nas Unidades Básicas de Saúde (UBS) do município de Londrina, Paraná. As características sociodemográficas foram também analisadas. A situação quanto às próteses dentárias foi avaliada a partir de informações sobre seu uso e necessidade nos arcos superior e inferior. As observações ao exame levaram em conta os códigos e critérios preconizados pela Organização Mundial de Saúde (OMS). As informações sociodemográficas foram obtidas pela aplicação de um formulário estruturado, avaliando: sexo, idade, nível de escolaridade, estado conjugal, tipo de moradia, número de pessoas na casa, renda familiar. A idade dos 504 idosos avaliados envolveu entre 60 e 75 anos, sendo a maioria entre 65 e 74 anos (54,2%), do gênero feminino (66,3%), de procedência rural (53,8%), cor branca (62,1%) e com até 4 anos de estudo (80,6%). Destes idosos, 15,1% não usam qualquer tipo de prótese, 24,6% usam em uma arcada e 60,3% usam algum tipo de prótese nas duas arcadas. Quanto à necessidade de prótese, observou-se que 21,6% não necessitam de qualquer tipo de prótese, 19,4% necessitam em uma arcada e a maioria (58,9%) necessita nas duas arcadas. Somente houve dependência, estatisticamente significante, entre as variáveis de necessidade de prótese dentária e gênero, cor da pele e procedência. Sendo assim, pode-se concluir que a prevalência de necessidade de prótese é acentuada e existe uma demanda populacional para reabilitação protética. (AU)


This study evaluated the need and use of prosthesis among 504 independent elderly, registered in the Basic Health Units (BHU) of the city of Londrina, Paraná. Sociodemographic characteristics were also evaluated. The situation regarding dental prosthesis was evaluated based on information about their use and need in the upper and lower arches. The observations were performed according to the codes and criteria recommended by the World Health Organization (WHO). The sociodemographic information was obtained by applying a structured form, evaluating: gender, age, educational level, marital status, housing type, number of people living in the residence, family income. The age of the 504-elderly studied was between 65 and 74 years (54.2%), female (66.3%), rural origin (53.8%), white skin color (62.1%) and up to 4 years of schooling (80.6%). Of these elderly, 15.1% do not use any type of prosthesis, 24.6% use only in one dental arch and 60.3% use some type of prosthesis in both arches. Regarding the need of prosthesis, it was observed that 21.6% do not require any type of prosthesis, 19.4% need in one arch and the majority (58.9%) needs in both arches. There was only statistically significant dependence among the variables of need for dental prosthesis and gender, skin color and origin. Thus, it can be concluded that the prevalence of need for prosthetic is high and there is a population demand for prosthetic rehabilitation. (AU)

10.
J. health sci. (Londrina) ; 19(4)30/10/2017.
Article in Portuguese | LILACS | ID: biblio-877749

ABSTRACT

Facetas cerâmicas fornecem resultados estéticos satisfatórios, preservando a estrutura dentária. A cerâmica dental pode melhorar a aparência estética e restabelecer a resistência e a função dos dentes. Nos dentes anteriores restaurados, as superfícies funcionais, por exemplo, em orientação anterior e lateral podem ser restauradas efetivamente. As características da cerâmica dental, como a estabilidade da cor e as propriedades mecânicas e ópticas, tornam este material uma boa escolha para restaurações indiretas, especialmente, quando são necessárias funções ótimas e a estética. Além disso, o dissilicato de lítio é uma cerâmica dental, que imita a estética e a resistência da estrutura dentária natural e foi utilizado no presente relato de caso clínico. (AU)


Ceramic veneers provide satisfactory esthetic outcomes while preserving the dental structure. Dental ceramics can both improve the esthetic appearance and reestablish the teeth's strength and function. In restored anterior teeth, functional surfaces, for example, anterior and lateral guidance, can be restored effectively. The characteristics of dental ceramics, such as color stability and mechanical and optical properties, make this material a good choice for indirect restorations, especially when optimum function and esthetics are required. Moreover, lithium disilicate is a dental ceramic that mimics the esthetics and strength of the natural tooth structure and it was used in the present clinical case report. (AU)

11.
Braz. dent. j ; 28(5): 618-623, Sept.-Oct. 2017. tab
Article in English | LILACS | ID: biblio-888680

ABSTRACT

Abstract The aim of this study was to evaluate the efficacy of applying sonic energy on microtensile bond strength and microhardness after the restoration process. A total of 40 human third molars were extracted. Class II cavities were prepared and restored with composite SonicFill or Filtek Z350 XT with and without the application of sonic energy. After the teeth were stored in water for 24 h, the teeth were sectioned into sticks (1.0 mm2) and subjected to tensile testing. For a depth Knoop hardness test, the samples were cut and indentations were made sequentially from the surface of the samples to the bottom of the samples in three intervals of 1 mm each. The samples were then subjected to a load of 50 g for 10 s. The results from the tensile (factors: placement system and composite) and hardness (factors: placement system, composite and depth) tests were subjected to the Kolmogorov-Smirnov normality test, followed by analysis of variance and Tukey's test (5% significance). For the placement system factor, higher bond strength was observed for the cavities that were restored with sonic energy (p < 0.001). For depth Knoop hardness, the hardness at 1 mm depth was significantly greater than that at 3 mm depth just for the restorations with Filtek Z350 XT composite without the application of sonic energy. Therefore, the use of sonic energy during the restorative process improved bonding, yet it did not markedly affect the depth hardness for both composites.


Resumo O objetivo deste estudo foi avaliar a eficácia da aplicação de energia sônica sobre a resistência de união à microtração e a microdureza após o processo de restauração. Um total de 40 terceiros molares humanos foram extraídos. Cavidades Classe II foram preparadas e restauradas com os compósitos SonicFill ou Filtek Z350 XT com e sem a aplicação de energia sônica. Após os dentes serem armazenados em água durante 24 h, foram seccionados em palitos (1,0 mm2) e submetidos a ensaio de tração. Para um ensaio de dureza Knoop de profundidade, as amostras foram cortadas e as penetrações foram feitas sequencialmente a partir da superfície para o fundo das amostras em três intervalos de 1 mm cada. As amostras foram então submetidas a uma carga de 50 g durante 10 s. Os resultados dos testes de tração (fatores: sistema de inserção e compósito) e dureza (fatores: sistema de inserção x compósito x profundidade) foram submetidos ao teste de normalidade Kolmogorov-Smirnov, seguido da análise de variância e do teste de Tukey (significância de 5%). Para o fator sistema de inserção, observou-se maior resistência de união para as cavidades que foram restauradas com energia sônica (p < 0,001). Para a dureza Knoop de profundidade, a dureza a 1 mm de profundidade foi significativamente maior do que a profundidade de 3 mm apenas para as restaurações com o compósito Filtek Z350 XT sem a aplicação de energia sônica. Portanto, o uso de energia sônica durante o processo restaurador melhorou a união, mas não afetou acentuadamente a dureza de profundidade para ambos os compósitos.


Subject(s)
Humans , Composite Resins/chemistry , Dental Restoration, Permanent/methods , Hardness Tests , Tensile Strength
12.
Acta odontol. latinoam ; 30(1): 13-18, 2017. tab
Article in English | LILACS | ID: biblio-907402

ABSTRACT

This study compared the surface detail reproduction anddimensional accuracy of molds after disinfection using 2% sodium hypochlorite, 2% chlorhexidine digluconate or 0.2% peracetic acid to those of molds that were not disinfected, forfour elastomeric impression materials: polysulfide (Light Bodied Permlastic), polyether (Impregum Soft), polydimethylsiloxane(Oranwash L) and polyvinylsiloxane (Aquasil Ultra LV). Themolds were prepared on a matrix by applying pressure, using aperforated metal tray. The molds were removed followingpolymerization and either disinfected (by soaking in one of thesolutions for 15 minutes) or not disinfected. The samples werethus divided into 16 groups (n=5). Surface detail reproductionand dimensional accuracy were evaluated using opticalmicroscopy to assess the 20 ­µm line over its entire 25 mm length. The dimensional accuracy results (%) were subjectedto analysis of variance (ANOVA) and the means were comparedby Tukey’s test (α=5%). The 20 ­µm line was completelyreproduced by all elastomeric impression materials, regardlessof disinfection procedure. There was no significant difference between the control group and molds disinfected with peraceticacid for the elastomeric materials Impregum Soft (polyether)and Aquasil Ultra LV (polyvinylsiloxane). The high­leveldisinfectant peracetic acid would be the choice material for disinfection.


Este estudo comparou a reprodução de detalhes da superfície e estabilidade dimensional de moldes obtidos após desinfecção utilizando hipoclorito de sódio 2%, digluconato de clorexidina 2%, ou ácido peracético 0,2% a moldes que não foram desinfetados com quatro elastômeros: polissulfeto (Light Bodied Permlastic), polieter (Impregum Soft), silicona reação porcondensação (Oranwash L) e silicona reação por adição (Aquasil Ultra LV). Os moldes foram preparados sobre matriz conten dolinhas de 20, 50 e 75 µm realizado sob pressão com moldeirade metal perfurada. Os moldes foram removidos após a polimerização e desinfetados (utilizando uma das soluções porimersão, armazenados em frascos fechados durante 15 minutos)ou não desinfetados. Assim, as amostras foram divididas em 16grupos (n=5). A reprodução detalhes da superfície e a precisão dimensional foram avaliadas usando microscopia óptica na linha 20 µm com 25 mm de comprimento, de acordo com a norma ISO 4823. Os resultados de precisão dimensional (%) foram submetidos à análise de variância (A NOVA) e as médias comparadas pelo teste de Tukey com 5% de nível de significância. A linha de 20 µm foi completamente reproduzida por todos os elastômeros, independentemente do processo de desinfecção. Não houve diferença estatisticamente significativa entre o grupo controle e moldes desinfetados com acido peracético para os elastômeros Impregum Soft (polieter) e Aquasil Ultra LV (siliconareação por adição). O desinfetante de alto nível ácido peracético seria o material de escolha para a desinfecção.


Subject(s)
Humans , Dental Impression Materials , Models, Dental , Dental Disinfectants/chemistry , Surface Properties , Analysis of Variance , Chlorhexidine/chemistry , Dimensional Measurement Accuracy , Edetic Acid/chemistry , Elastomers/classification , Microscopy/methods , Data Interpretation, Statistical , Siloxanes/classification , Sodium Hypochlorite/chemistry , Sulfides/classification
13.
Braz. dent. j ; 27(4): 458-462, July-Aug. 2016. tab, graf
Article in English | LILACS | ID: lil-794612

ABSTRACT

Abstract The purpose of this study was to evaluate the microshear bond strength of ceramic prosthetic structures reinforced by lithium disilicate cemented with resin cement under conditions of different surface treatments and adhesive systems. Seventy-two rectangular blocks of lithium disilicate (6.5 mm long × 5 mm wide × 1 mm thick) were fabricated, air abraded with 50-μm Al2O3 particles and divided into six groups (n=12) depending on the surface pretreatments. The groups were as follows: 10HF/S/SBM: 10% hydrofluoric acid etched for 20 s (10HF) + silane (S) + Adper Scotchbond Multi-Purpose (SBM); 10HF/S/SB: 10HF + S + Single Bond Universal (SB); 10HF/SBM; 10HF/SB; S/SBM and S/SB. Two 1-mm-long plastic tubes were placed on the specimens, filled with RelyX ARC resin cement and cured for 20 s per tube. The plastic tube was removed, and the microshear bond strength was tested. Data were submitted to analysis of variance and Tukey's tests (α=0.05). Fractured specimens were observed under optical microscopy. For both adhesives, the bond strengths (MPa) of groups treated with acid-etching and silane (10HF/S/SB: 24.82, 10HF/S/SBM: 24.90) were higher (p<0.001) than those of groups treated with acid-etching (10HF/SB: 16.47, 10HF/SBM: 19.94) only or only silane (S/SB: 18.42, S/SBM: 13.24). All groups showed a predominance of failure adhesive. The silanization should be a clinical step in cementing ceramic structures reinforced by lithium disilicate, even with the application of universal adhesive that contains silane in its formulation.


Resumo O objetivo neste estudo foi avaliar a resistência de união ao microcisalhamento de estruturas protéticas cerâmicas reforçadas por dissilicato de lítio cimentadas com cimento resinoso sob diferentes tratamentos de superfície e sistemas adesivos. Setenta e duas barras retangulares de dissilicato de lítio (6,5 mm de comprimento × 5 mm de largura × 1 mm de espessura) foram fabricadas, tratados com partículas de Al2O3 (50 μm) e dividido em seis grupos (n=12) dependendo dos pré-tratamentos de superfície. Os grupos foram como se segue: 10HF/S/SBM: condicionamento com ácido fluorídrico 10% durante 20 s (10HF) + silano (S) + Adper Scotchbond Multi-Purpose (SBM); 10HF/S/SB: 10HF + S + Single Bond Universal (SB); 10HF/SBM; 10HF/SB; S/SBM; e S/SB. Dois tubos plásticos cilíndricos de 1 mm de comprimento foram colocados sobre os espécimes, preenchidos com cimento RelyX ARC e fotoativado durante 20 s por tubo. Os tubos plásticos foram removidos e a resistência de união ao microcisalhamento foi testada. Os dados foram submetidos à análise de variância e ao teste de Tukey (α=0,05). Espécimes fraturados foram observados sob microscopia óptica. Para ambos os adesivos, a resistência de união (MPa) dos grupos tratados com condicionamento ácido e silano (10HF/S/SB: 24,82, 10HF/S/SBM: 24,90) foram superiores (p<0.001) aos grupos tratados com condicionamento ácido apenas (10HF/SB: 16,47, 10HF/SBM: 19,94) ou apenas silano (S/SB: 18,42, S/SBM: 13,24). Todos os grupos apresentaram uma predominância de falha adesiva. A silanização deve ser um passo clínico em cimentação de estruturas cerâmicas reforçadas por dissilicato de lítio, mesmo com a aplicação do adesivo universal que contém em sua formulação um silano.


Subject(s)
Dental Porcelain/chemistry , Materials Testing , Surface Properties
14.
J. health sci. (Londrina) ; 18(3): 188-194, 31/07/2016.
Article in Portuguese | LILACS | ID: biblio-831804

ABSTRACT

Com advento das resinas compostas de segunda geração que apresentam características mecânicas e estéticas superiores às das resinas convencionais, principalmente com relação a resistência à abrasão, surge a possibilidade de utilizá-las associadas a fibras, como o sistema da Ivoclar Targis/Vectris. O objetivo deste trabalho foi apresentar a confecção de uma prótese adesiva livre de metal, como resolução protética para a substituição do elemento dental 35, ausente. Paciente M.A.S., 38 anos, sexo feminino, buscou tratamento restaurador por motivo de estética e necessidade de substituição das restaurações antigas. Após anamnese, exame clínico, exame radiográfico e exame dos modelos de estudo, foi proposta a reposição do elemento dental 35, através de prótese adesiva confeccionada em cerômero (Sistema Targis/Vectris. Foi realizado um repreparo do tipo onlay no elemento dental 34 e repreparo para coroa total do dente 36. Após o término dos preparos, foi feita a moldagem utilizando-se a técnica da dupla moldagem e confecção da restauração provisória, envolvendo os três elementos com resina acrílica. Na segunda sessão, a peça protética foi cimentada, a oclusão verificada e ajustada. Uma vez que os cerômeros têm boa resistência de união e semelhante à das cerâmicas, além de apresentarem caraterísticas mecânicas muito semelhantes à estrutura dental, eles conseguem atuar de forma satisfatória na distribuição das cargas oclusais em dentes posteriores. Assim, pode-se concluir que as restaurações livres de metal são ótimas alternativas para proporcionar à paciente uma melhora estética e funcional, além de integridade das margens e do periodonto, estabilidade estrutural, retenção e resistência da restauração.


With advent of second generation composite resins that showed superior mechanical and esthetic characteristics when compared to the conventional resins, particularly regarding abrasion resistance, they can be used in association with fibers, such as the Ivoclar Targis/Vectris system. The objective of this study was to develop a metal free adhesive denture as prosthetic resolution to replace the missed dental element 35. Patient M.A.S., 38 years-old, female, looked for restorative treatment due to esthetic reasons and need for replacement of old restorations. After anamnesis, clinical, radiographic, and study models examination, the replacement of the dental element 35 through ceromer adhesive prosthesis (Targis-Vectris system) was proposed. The dental element 34 was re-prepared for onlay, and the tooth 36 re-prepared for a total crown. Impression was made using double impression technique, and a 3-element temporary restoration with acrylic resin was made. At the second session, the prosthetic restoration was cemented, and the occlusion checked and adjusted. Ceromers have bond strength similar to ceramics and mechanical characteristics close to teeth, which makes a satisfactory force distribution of the occlusal load on posterior teeth. Thus, it can be concluded that ceromer restorations can be excellent alternatives to provide the patient esthetic and function, besides the marginal and periodontium integrity, structural stability, retention, and restoration strength.

15.
Braz. dent. j ; 26(3): 222-227, May-Jun/2015. tab, graf
Article in English | LILACS | ID: lil-751866

ABSTRACT

Endodontic posts are necessary to provide adequate retention and support when no sufficient remaining structure is available to retain the core. There are different materials and techniques to construct post-and-core, but there is no consensus about which one promotes better stress distribution on the remaining tooth structure. This study aimed to quantify and evaluate the distribution of stress in the root produced by customized glass fiber posts compared to different endodontic posts. Twenty-five simulated roots from photoelastic resin were made and divided into 5 groups: CPC, cast post-and-core; SP, screw post; CF, carbon fiber post; GF, glass fiber post; and CGF, customized glass fiber post. After cementing CPC and SP posts with zinc phosphate cement, and CF, GF and CGF posts with resin cement, resin cores were made for groups 2-5. Specimens were evaluated with vertical or 45° oblique loading. To analyze the fringes, the root was divided into 6 parts: palatal cervical, palatal middle, palatal apical, vestibular cervical, vestibular middle, and vestibular apical. The formed fringes were photographed and quantified. Data were recorded and subjected to two-way ANOVA and Tukey's test (5%). SP (1.95±0.60) showed higher stress (p<0.05) compared to the others (CPC-0.52±0.74; CF-0.50±0.75, GF-0.23±0.48 and CGF-0.45±0.83). All posts showed high stress in apical third (CPC-1.40±0.65; SP-2.30±0.44, CF-1.80±0.45, GF-1.20±0.45, CGF-1.70±1.03) Low stress was found in cervical third (CPC-0.20±0.45; CF-0.00±0.00, GF-0.00±0.00, CGF-0.00±0.00), except by SP (1.90±0.65), which showed statistical difference (p<0.05). Customized post showed high stress concentration at the root and conventional glass fiber posts showed more favorable biomechanical behavior.


Pinos endodônticos são necessários para promover retenção e suporte adequados quando a estrutura dental remanescente não é suficiente para reter o núcleo. Há diferentes materiais e técnicas para construir o núcleo, mas não há consenso sobre o qual promove a melhor distribuição de tensão na estrutura dental remanescente. O objetivo deste trabalho foi quantificar e avaliar a distribuição de tensões produzidas nas raízes por pinos de fibra de vidro customizados quando comparados a diferentes pinos endodônticos. Vinte e cinco raízes simuladas em resina fotoelástica foram confeccionadas e divididas em 5 grupos: CPC, núcleo metálico fundido, SP, pino rosqueável; CF, pino de fibra de carbono; GF, pino de fibra de vidro; CGF, pino de fibra de vidro customizado. Depois da cimentação dos pinos de CPC e SP com cimento de fosfato de zinco e dos pinos de CF, GF e CGF com cimento resinoso, núcleos em resina foram feitos para os grupos 2-5. Os espécimes foram avaliados com carga vertical ou oblíqua a 45o. Para analisar as franjas, a área da raiz foi dividida em 6 partes: palatina cervical, palatina média, palatina apical, vestibular cervical, vestibular média e vestibular apical. As franjas formadas foram fotografadas e quantificadas. Os dados foram gravados e submetidos à ANOVA de dois fatores e ao teste de Tukey (5%). SP (1,95±0,60) mostrou maior tensão (p<0,05) quando comparado com os demais (CPC - 0,52±0,74; CF - 0,50±0,75, GF - 0,23±0,48, CGF - 0,45±0,83). Todos os pinos mostraram maior tensão no terço apical (CPC - 1,40±0,65; SP - 2,30±0,44, CF - 1,80±0,45, GF - 1,20±0,45, CGF - 1,70±1,03) Menor tensão foi encontrado no terço cervical (CPC - 0,20±0.45; CF - 0,00±0 00, GF - 0 ,0±0,00, CGF - 0,00±0,00), exceto pelo SP (1,90±0,65), que não apresentou diferença estatística (p<0,05). Pinos customizados de fibra de vidro mostraram maior concentração de estresse na raiz quando comparados com pinos convencionais de fibra de vidro, que se mostraram com comportamento biomecânico mais favorável.


Subject(s)
Dental Stress Analysis , Post and Core Technique , Elasticity , Glass , Tooth Root
16.
Ortodontia ; 47(5): 441-448, set.-out. 2014. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-760088

ABSTRACT

O objetivo deste estudo foi avaliar e quantificar, in vitro, a tensão resultante nas estruturas de suporte durante a retração de um canino superior com, o uso do método mini-implante e power arm, por meio da fotoelasticidade. Foram utilizados 15 modelos em resina fotoelástica representando um hemiarco superior direito com a ausência do primeiro pré-molar. Nos referidos dentes, foram colados braquetes convencionais (3M-Unitek, prescrição MBT .022”) e tubos nos molares (3M-Unitek, prescrição MBT .022”), os quais receberam um fio de NiTi (Orthometric, .016” x .022”). Foram adaptados dispositivos power arm nos braquetes dos caninos, nos tamanhos: curto, médio e longo, passando abaixo, na altura e acima do centro de resistência do canino, respectivamente. Na região vestibular, entre as raízes do segundo pré-molar e primeiro molar, foi posicionado um mini-implante. Uma mola de retração de 150 g (GAC, NiTi) foi conectada do mini-implante ao dispositivo power arm. A tensão gerada foi analisada ao longo da raiz do canino por meio de um polariscópio de reflexão, o qual quantificou as tensões (Mpa) por meio de um software (OS CALC 2.0). A análise estatística foi realizada pelo teste Anova seguido do teste de Tukey a 0,05% de significância. Os resultados obtidos revelaram que o power arm médio foi o mais eficiente para a realização do movimento de translação durante a retração do canino, quando comparado aos de tamanho curto e longo. Concluiu-se que para a retração de caninos, quando a finalidade é um movimento de corpo, o tamanho do power arm deve coincidir com a altura do centro de resistência do mesmo.


The aim of this study was to evaluate and quantify in vitro, the resulting tension in the supporting structures during retraction of a maxillary canine using the mini-implant and method power arm through photoelasticity. A total of 15 models in photoelastic resin representing a hemi-arch top right with the absence of the first premolar, and the presence of incisors, canine, second premolar, first and second molar. In those teeth were glued conventional brackets (3M-Unitek, prescription MBT .022 ") and tubes in the first and second molar (3M-Unitek, prescription MBT .022"), which received a wire NiTi (Orthometric, .016" x .022"). We adapted devices power arm in canine brackets in sizes: short, medium and long, going below the center of resistance, the height of the center of resistance and above the center of resistance of the tooth, respectively. For each device size power arm to be adopted, 5 models were manufactured in photoelastic resin. In the vestibular region, between the roots of the second premolar and first molar was positioned a mini implant to 5 mm apical to the cervical third. A spring retraction 150 g (GAC, NiTi) was connected to the mini-implant device power arm. The voltage generated was analyzed along the root of the canine by means of a polariscope using the reflection method, which quantified the stresses (MPa) through a software (OS CALC 2.0). Statistical analysis was performed by Anova followed by Tukey test at 0,05% significance. The results revealed that the average power arm was more efficient to perform the translation movement during retraction of the canine when compared to short and long size. It is concluded that for canine retraction when the purpose is a motion of body, size of the power arm must match the height of its center of resistance thereof then being the average size of choice.


Subject(s)
Cuspid , Dental Implants , Tooth Movement Techniques , Orthodontic Anchorage Procedures , Tensile Strength
17.
Dental press j. orthod. (Impr.) ; 19(3): 114-119, May-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-723151

ABSTRACT

OBJECTIVE: To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. MATERIAL AND METHODS : Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a ligating wire 0.10-in was used to ligate the wire to the Abzil bracket. Three types of orthodontic archwire alloys were assessed: 0.016-in NiTi wire, 0.016 x 0.021-in NiTi wire and 0.019 x 0.025-in steel wire. Ten observations were carried out for each bracket-archwire angulation combination. Brackets were mounted in a special appliance, positioned at 90 degrees in relation to the wire and tested in two angulations. Frictional test was performed in a Universal Testing Machine at 5 mm/min and 10 mm of displacement. The means (MPa) were submitted to ANOVA and Tukey's test set at 5% of significance. The surfaces of wires and brackets were observed at SEM. RESULTS: Steel-tied brackets (16.48 ± 8.31) showed higher means of frictional resistance than elastomeric-tied brackets (4.29 ± 2.16 ) and self-ligating brackets (1.66 ± 1.57) (P < 0.05), which also differed from each other (P < 0.05). As for the type of wire, 0.019 x 0.025-in steel wire (5.67 ± 3.97) showed lower means (P < 0.05) than 0.16-in NiTi wire (8.26 ± 10.92) and 0.016 x 0.021-in NiTi wire (8.51 ± 7.95), which did not differ from each other (P > 0.05). No statistical differences (P > 0.05) were found between zero (7.76 ± 8.46) and five-degree (7.19 ± 7.93) angulations. CONCLUSIONS: Friction was influenced not only by the type of bracket, but also by the ligating systems. Different morphological aspects were observed for the brackets and wires studied .


OBJETIVO: comparar a resistência ao atrito entre braquetes autoligáveis e braquetes convencionais, variando o tipo de fio. MÉTODOS: foram usados braquetes incisivos Abzil Kirium Capelozza e Easy Clip. Uma ligadura elastomérica ou um fio ligável de 0,010" foi usado para ligação do fio no braquete Abzil. Três tipos de ligas de fio ortodôntico foram avaliadas: fio de NiTi de 0,016"; fio de NiTi de 0,016" x 0,022"; e fio de aço de 0,019" x 0,025". Dez observações foram feitas para cada combinação "braquete-fio-inclinação". Os braquetes foram montados em um aparelho especial, posicionados a 90° em relação ao fio, e testados em duas inclinações. O teste de atrito foi realizado na máquina universal de ensaios, a 5mm/min e com 10mm de deslocamento. As médias (em MPa) foram submetidas aos testes ANOVA e de Tukey, a 5% de significância. As superfícies dos fios e dos braquetes foram observadas no MEV. RESULTADOS: o braquete com amarrilhos metálicos (16,48 ± 8,31MPa) apresentou médias mais altas que o braquete com ligaduras elastoméricas (4,29 ± 2,16MPa) e o braquete autoligável (1,66 ± 1,57) (p < 0,05), os quais também diferiram entre si (p < 0,05). Quanto ao tipo do fio, o fio de aço de 0,019" x 0,025" (5,67 ± 3,97MPa) apresentou médias mais baixas (p < 0,05) que os fios de NiTi de 0,016" (8,26 ± 10,92MPa) e de 0,016" x 0,022" (8,51 ± 7,95), os quais não diferiram entre si (p > 0,05). Nenhuma diferença estatística (p > 0,05) foi encontrada entre inclinações de zero (7,76 ± 8,46) e cinco (7,19 ± 7,93) graus. Concluão: o atrito foi influenciado pelo tipo de braquete e sistemas de ligaduras. Diferentes aspectos morfológicos foram observados para os braquetes e fios estudados. .


Subject(s)
Humans , Dental Alloys/chemistry , Dental Materials/chemistry , Elastomers/chemistry , Orthodontic Appliance Design , Orthodontic Brackets , Orthodontic Wires , Alloys/chemistry , Dental Stress Analysis/instrumentation , Friction , Materials Testing , Microscopy, Electron, Scanning , Nickel/chemistry , Stress, Mechanical , Surface Properties , Stainless Steel/chemistry , Titanium/chemistry
18.
Braz. dent. j ; 23(1): 3-7, 2012. ilus, tab
Article in English | LILACS | ID: lil-617997

ABSTRACT

The mismatch of thermal expansion and contraction between restorative materials and tooth may cause stresses at their interface, which may lead to microleakage. The present work compared the coefficient of thermal expansion (CTE) with the thermomechanical behavior of human and bovine teeth and determined if the CTE is a suitable parameter to describe tooth behavior. Fifteen human third molar and 15 bovine incisor tooth slices (6×5×2 mm) were allocated to 3 groups according to the test environment: G1 - room condition, G2 - 100 percent humidity, G3 - desiccated and tested in dry condition. Each specimen was weighed, heated from 20 to 70ºC at 10ºC min−1 and reweighed. The CTE was measured between 20 and 50ºC. Fresh dentin (human -0.49 percent ± 0.27, bovine -0.22 percent ± 0.16) contracted on heating under dry condition. Under wet conditions, only human teeth (-0.05 percent ± 0.04) showed contraction (bovine 0.00 percent ± 0.03) accompanied by a significantly lower (p<0.05) weight loss than in dry specimens (human 0.35 percent ± 0.15, bovine 0.45 percent ± 0.20). The desiccated dentin expanded on heating without obvious weight changes (0.00 percent ± 0.00). The CTE found was, respectively, in dry, wet and dissected conditions in ºC-1: human (-66.03×10-6, -6.82×10-6, 5.52×10-6) and bovine (-33.71×10-6, 5.47×10-6, 4.31×10-6). According to its wet condition, the dentin showed different CTEs. The thermal expansion behavior of human and bovine dentin was similar. A simple evaluation of the thermal expansion behavior of tooth structure by its CTE value may not be appropriate as a meaningful consideration of the effects on the tooth-material interface.


A discrepância entre a expansão e a contração térmica dos materiais restauradores e o dente podem causar estresse na sua interface, podendo levar a uma microinfiltração. O presente trabalho determinou e comparou o coeficiente de expansão térmica (CET) com o comportamento termo mecânico dos dentes humanos e bovinos e determinou se o CET é um parâmetro adequado para descrever o comportamento dental. 15 fatias (6×5×2 mm) de terceiros molares humanos e 15 de incisivos bovinos foram divididos em 3 grupos de acordo com o ambiente testado: G1 - condição ambiente, G2 - 100 por cento de umidade, G3 - dissecado e testado em condição seca. Cada espécime foi pesado, aquecido de 20 a 70C a 10ºC min-1 e pesados novamente. O CET foi mensurado entre 20 e 50ºC. Dentina fresca (humana -0,49 por cento ± 0,27, bovina -0,22 por cento ± 0,16) contrai no aquecimento sobre condição seca. Em condição úmida, somente dente humano (-0,05 por cento ± 0,04) mostrou contração (bovina 0,00 por cento ± 0,03) acompanhado por uma significante (p<0.05) perda de massa que os espécimes secos. A dentina dissecada expande no aquecimento sem mudanças óbvias de peso (0,00 por cento ± 0,00). O CET encontrado foi, respectivamente, em condições seca, úmida e dissecada em ºC-1: humana (-66,03×10-6, -6,82×10-6, 5,52×10-6) e bovina (-33,71×10-6, 5,47×10-6, 4,31×10-6). De acordo com sua condição de umidade, a dentina mostrou diferentes CETs. O comportamento de expansão térmica de dentes humanos e bovinos é similar. Uma simples avaliação do coeficiente de expansão térmica da estrutura dental pelo seu valor de CET pode não ser apropriada para uma consideração significativa dos efeitos na interface dente-material restaurador.


Subject(s)
Animals , Cattle , Humans , Dentin/chemistry , Humidity , Temperature , Analysis of Variance
19.
Braz. dent. j ; 23(6): 692-697, 2012. ilus, tab
Article in English | LILACS | ID: lil-662428

ABSTRACT

This study evaluated the effectiveness of different sealants applied to a nanofiller composite resin. Forty specimens of Filtek Z-350 were obtained after inserting the material in a 6x3 mm stainless steel mold followed by light activation for 20 s. The groups were divided (n=10) according to the surface treatment applied: Control group (no surface treatment), Fortify, Fortify Plus and Biscover LV. The specimens were subjected to simulated toothbrushing using a 200 g load and 250 strokes/min to simulate 1 week, 1, 3 and 6 months and 1 and 3 years in the mouth, considering 10,000 cycles equivalent to 1 year of toothbrushing. Oral-B soft-bristle-tip toothbrush heads and Colgate Total dentifrice at a 1:2 water-dilution were used. After each simulated time, surface roughness was assessed in random triplicate readings. The data were submitted to two-way ANOVA and Tukey's test at a 95% confidence level. The specimens were observed under scanning electron microscopy (SEM) after each toothbrushing cycle. The control group was not significantly different (p>0.05) from the other groups, except for Fortify Plus (p<0.05), which was rougher. No significant differences (p>0.05) were observed at the 1-month assessment between the experimental and control groups. Fortify and Fortify Plus presented a rougher surface over time, differing from the baseline (p<0.05). Biscover LV did not differ (p>0.05) from the baseline at any time. None of the experimental groups showed a significantly better performance (p>0.05) than the control group at any time. SEM confirmed the differences found during the roughness testing. Surface penetrating sealants did not improve the roughness of nanofiller composite resin.


Este estudo avaliou a efetividade de diferentes selantes aplicados a uma resina nanoparticulada. Quarenta espécimes de Filtek Z-350 foram obtidos depois da inserção do material em um molde de aço inoxidável seguido por fotoativação por 20 s. Os grupos foram divididos (n=10) de acordo com o tratamento superficial aplicado: Grupo controle (sem tratamento superficial), Fortify, Fortify Plus ou Biscover LV. Os espécimes foram submetidos a escovação simulada usando uma carga de 200 g e 250 ciclos/min para simular 1 semana, 1, 3 e 6 meses e 1 e 3 anos, considerando que 10.000 ciclos equivalem a um ano de escovação. Escovas Oral-B de cabeça macia e dentifrício Colgate Total diluído a 1:2 em água foram utilizados. Depois de cada período de simulação, a rugosidade superficial foi medida em triplicata. Os dados foram submetidos à ANOVA de dois fatores e ao teste de Tukey com nível de 95% de confiança. Os espécimes foram observados em microscopia eletrônica de varredura (MEV) depois de cada ciclo de escovação. O grupo controle não foi diferente (p>0,05) que os outros grupos, exceto pelo Fortify Plus (p<0,05), que foi mais rugoso. Nenhuma diferença (p>0,05) foi observada em 1 mês de simulação entre os grupos experimentais e o controle. Fortify e Fortify Plus apresentaram rugosidade regular com o tempo, diferindo da inicial em todos os tempos. Nenhum dos grupos selados mostrou melhor desempenho (p>0,05) que o grupo controle em qualquer um dos tempos. MEV ressaltou as diferenças encontradas durante o teste de rugosidade. Selantes de penetração de superfície não melhoram a rugosidade da resina nanoparticulada.


Subject(s)
Humans , Composite Resins/chemistry , Dental Materials/chemistry , Nanocomposites/chemistry , Resin Cements/chemistry , Acrylates/chemistry , Light-Curing of Dental Adhesives , Materials Testing , Microscopy, Electron, Scanning , Polymerization , Stress, Mechanical , Surface Properties , Time Factors , Toothbrushing/instrumentation , Toothpastes/chemistry
20.
Braz. oral res ; 25(4): 302-306, July-Aug. 2011. ilus
Article in English | LILACS | ID: lil-595848

ABSTRACT

Silorane-based composite, an epoxy material, was marketed as promising less polymerization contraction than conventional restorative materials. The aim of this study was to evaluate, by means of photoelasticity, the polymerization stress generated by a silorane-based composite. Thirty photoelastic rings with orifices measuring 5 mm (d) × 3 mm (h) were prepared and divided into 6 groups (n = 5) according to the material tested. The inside walls of the rings were sandblasted with aluminum oxide, after which the restorative materials were inserted into the orifices and photoactivated according to the manufacturer's instructions. The specimens were analyzed and the visual representation of the stress was measured considering the isochromatic ring of first order. The data were converted to MPa and subjected to ANOVA and Tukey's test (α= 0.05). The adhesive Filtek P-90 (G5) showed high contraction stress (p < 0.05) when compared to G1, G2, G3, G4, and G6, which did not differ from each other (p > 0.05). The composite Filtek P-90 showed similar contraction stress compared to the conventional composite and, additionally, its adhesive showed higher stress than did the etch-and-rinse 2-step adhesive.


Subject(s)
Composite Resins/chemistry , Dental Stress Analysis/methods , Dentin-Bonding Agents/chemistry , Analysis of Variance , Elastic Modulus , Elasticity , Materials Testing , Polymerization , Stress, Mechanical